 BL0955 Single-Phase Energy MeteringIC (compatible with AD7755)
GENERAL DESCRIPTION:
The BL0955 is a high accuracy electrical energy measurement IC. The part specifications surpass the accuracy requirements as quoted in the IEC1036 standard. See Analog Devices' Application Note AN-559 for a description of an IEC1036 watt-hour meter reference design. The only analog circuitry used in the BL0955 is in the ADCs and reference circuit. All other signal processing (e.g., multiplication and filtering) is carried out in the digital domain. This approach provides superior stability and accuracy over extremes in environmental conditions and over time. The BL0955 supplies average real power information on the low frequency outputs F1 and
F2. These logic outputs may be used to directly drive an electromechanical counter or interface to an MCU. The CF logic output gives instantaneous real power information. This output is intended to be used for calibration purposes, or interfacing to an MCU. The BL0955 includes a power supply monitoring circuit on the AVDD supply pin. The BL0955 will remain in a reset condition until the supply voltage on AVDD reaches 4 V. If the supply falls below 4 V, the BL0955 will also be reset and no pulses will be issued on F1, F2 and CF.
w
w
w
da .
sh ta
t4 ee
. u
om c
The BL0955 is available in 24-lead DIP and SSOP packages.
SSOP24 DIP24
Address
No.810, YiShan Road ShangHai China Tel
86-021-64850700 Fax
86-64852222 Zip.200233
ww..com
Internal phase matching circuitry ensures that the voltage and current channels are phase matched whether the HPF in Channel 1 is on or off. An internal no-load threshold ensures that the BL0955 does not exhibit any creep when there is no load.
BL0955 Single-Phase Energy MeteringIC (compatible with AD7755)
FEATURE: .High Accuracy, Supports 50 Hz/60 Hz IEC 687/1036 Less than 0.1% Error Over a Dynamic Range of 500 to 1 .The BL0955 Supplies Average Real Power on the Frequency Outputs F1 and F2 .The High Frequency Output CF Is Intended for Calibration and Supplies Instantaneous Real Power .The Logic Output REVP Can Be Used to Indicate a Potential Miswiring or Negative Power .Direct Drive for Electromechanical Counters and Two Phase Stepper Motors (F1 and F2) .A PGA in the Current Channel Allows the Use of Small Values of Shunt and Burden Resistance .Proprietary ADCs and DSP Provide High Accuracy over Large Variations in Environmental Conditions and Time .On-Chip Power Supply Monitoring .On-Chip Creep Protection (No Load Threshold) .On-Chip Reference 2.5 V _ 8% (30 ppm/_C Typical) with External Overdrive Capability .Single 5 V Supply, Low Power (15 mW Typical) .Low Cost CMOS Process
Address
No.810, YiShan Road ShangHai China Tel
86-021-64850700 Fax
86-64852222 Zip.200233
BL0955 Single-Phase Energy MeteringIC (compatible with AD7755)
Address
No.810, YiShan Road ShangHai China Tel
86-021-64850700 Fax
86-64852222 Zip.200233
BL0955 Single-Phase Energy MeteringIC (compatible with AD7755)
NOTES 1 See Terminology Section for explanation of specifications. 2 See Plots in Typical Performance Graphs. 3Sample tested during initial release and after any redesign or process change that may affect this parameter. Specifications subject to change without notice.
NOTES 1 Sample tested during initial release and after any redesign or process change that may affect this parameter. 2 See Figure 1. 3 The pulsewidths of F1, F2 and CF are not fixed for higher output frequencies. See Frequency Outputs Section. 4 The CF pulse is always 18 |I s in the high frequency mode. See Frequency Outputs section and Table IV. Specifications subject to change without notice.
Figure1. Timing Diagram for Frequency Outputs ABSOLUTE MAXIMUM RATINGS* (TA = +25a C unless otherwise noted) AVDD to AGND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . .-0.3 V to +7 V DVDD to DGND . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . .. . . . . . . . . .. . . . .-0.3 V to +7 V
Address No.810, YiShan Road ShangHai China Tel 86-021-64850700 Fax 86-64852222 Zip.200233
BL0955 Single-Phase Energy MeteringIC (compatible with AD7755) DVDD to AVDD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . -0.3 V to +0.3 V Analog Input Voltage to AGND V1P, V1N, V2P and V2N . . . . . . . . . . . . . . . . -6 V to +6 V Reference Input Voltage to AGND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.3 V to AVDD + 0.3 V Digital Input Voltage to DGND . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . .. . -0.3 V to DVDD + 0.3 V Digital Output Voltage to DGND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. -0.3 V to DVDD + 0.3 V Operating Temperature Range Industrial (A, B Versions) . . . . . . . . . . . . . . . . . -40a C to +85a C C
Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . -65a C to +150a Junction Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . .. . . . . +150a C 24-Lead Plastic DIP, Power Dissipation . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . 450 mW
JA Thermal Impedance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . 105a C/W
Lead Temperature, (Soldering 10 sec) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +260a C 24-Lead SSOP, Power Dissipation . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . 450 mW
JA Thermal Impedance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . 112a C/W
Lead Temperature, Soldering Vapor Phase (60 sec) . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . .. . . . . . . . . . . . . . +215a C Infrared (15 sec) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . .. . . . . . . . . . . . . . . . +220a C *Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those listed in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. CAUTION ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection. Although the BL0955 features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance degradation or loss of functionality. TERMINOLOGY MEASUREMENT ERROR The error associated with the energy measurement made by the BL0955 is defined by the following formula:
Pencentage Error =
Energy Re gistered by the BL0955 - True Energy x 100% True Energy
PHASE ERROR BETWEEN CHANNELS The HPF (High Pass Filter) in Channel 1 has a phase lead response. To offset this phase response and
Address No.810, YiShan Road ShangHai China Tel 86-021-64850700 Fax 86-64852222 Zip.200233
BL0955 Single-Phase Energy MeteringIC (compatible with AD7755) equalize the phase response between channels, a phase correction network is also placed in Channel 1. The phase correction network matches the phase to within A 0.1a over a range of 45 Hz to 65 Hz and A 0.2a over a range 40Hz to 1kHz. See Figures 22 and 23. POWER SUPPLY REJECTION This quantifies the BL0955 measurement error as a percentage of reading when the power supplies are varied. For the ac PSR measurement a reading at nominal supplies (5 V) is taken. A 200 mV rms/100 Hz signal is then introduced onto the supplies and a second reading obtained under the same input signal levels. Any error introduced is expressed as a percentage of reading--see Measurement Error definition. For the dc PSR measurement a reading at nominal supplies (5 V) is taken. The supplies are then varied A 5% and a second reading is obtained with the same input signal levels. Any error introduced is again expressed as a percentage of reading. ADC OFFSET ERROR This refers to the dc offset associated with the analog inputs to the ADCs. It means that with the analog inputs connected to AGND the ADCs still see an analog input signal of 1 mV to 10 mV, depending on gain setting. However, when the HPF is switched on, the offset is removed from the current channel and the power calculation is not affected by this offset. GAIN ERROR The gain error of the BL0955 is defined as the difference between the measured output frequency (minus the offset) and the ideal output frequency. It is measured with a gain of 1 in channel V1. The difference is expressed as a percentage of the ideal frequency. The ideal frequency is obtained from the BL0955 transfer function--see Transfer Function section. GAIN ERROR MATCH The gain error match is defined as the gain error (minus the offset) obtained when switching between a gain of 1 and a gain of 2, 8, or 16. It is expressed as a percentage of the output frequency obtained under a gain of 1. This gives the gain error observed when the gain selection is changed from 1 to 2, 8 or 16.
ESD SENSITIVE DEVICE
Address
No.810, YiShan Road ShangHai China Tel
86-021-64850700 Fax
86-64852222 Zip.200233
BL0955 Single-Phase Energy MeteringIC (compatible with AD7755)
Address
No.810, YiShan Road ShangHai China Tel
86-021-64850700 Fax
86-64852222 Zip.200233
BL0955 Single-Phase Energy MeteringIC (compatible with AD7755)
Address
No.810, YiShan Road ShangHai China Tel
86-021-64850700 Fax
86-64852222 Zip.200233
BL0955 Single-Phase Energy MeteringIC (compatible with AD7755)
Typical Performance Characteristics--BL0955
Figure 2. Error as a% of Reading (Gain=1)
Figure 3. Error as a% of Reading (Gain=2)
Address
No.810, YiShan Road ShangHai China Tel
86-021-64850700 Fax
86-64852222 Zip.200233
BL0955 Single-Phase Energy MeteringIC (compatible with AD7755)
Figure 4. Error as a% of Reading (Gain=8)
Figure 5. Error as a% of Reading (Gain=16)
Address
No.810, YiShan Road ShangHai China Tel
86-021-64850700 Fax
86-64852222 Zip.200233
BL0955 Single-Phase Energy MeteringIC (compatible with AD7755)
Figure 6. Error as a% of Reading (Gain=1)
Figure 7. Error as a% of Reading (Gain=2)
Figure 8. Error as a% of Reading (Gain=8)
Figure 9. Error as a% of Reading (Gain=16)
Address
No.810, YiShan Road ShangHai China Tel
86-021-64850700 Fax
86-64852222 Zip.200233
BL0955 Single-Phase Energy MeteringIC (compatible with AD7755)
Figure 10. Error as a% of Reading over Temperature Figure 11. Error as a% of Reading over Temperature with an External Reference (Gain=2) with an External Reference (Gain=16)
Address
No.810, YiShan Road ShangHai China Tel
86-021-64850700 Fax
86-64852222 Zip.200233
BL0955 Single-Phase Energy MeteringIC (compatible with AD7755)
Figure 12. Error as a% of Reading over Frequency
Figure 13. Test Circuit for Performance Curves
Figure 14. Channel 1 Offset Distribution (Gain=1)
Figure 15. Channel 1 Offset Distribution (Gain=2)
Address
No.810, YiShan Road ShangHai China Tel
86-021-64850700 Fax
86-64852222 Zip.200233
BL0955 Single-Phase Energy MeteringIC (compatible with AD7755)
Figure 16. Channel 1 Offset Distribution (Gain=8) (Gain=16)
Figure 17. Channel 1 Offset Distribution
Address
No.810, YiShan Road ShangHai China Tel
86-021-64850700 Fax
86-64852222 Zip.200233
BL0955 Single-Phase Energy MeteringIC (compatible with AD7755)
Figure 18. PSR with Internal Reference (Gain=16) (Gain=16)
Figure 19. PSR with external Reference
THEORY OF OPERATION The two ADCs digitize the voltage signals from the current and voltage transducers. These ADCs are 16-bit second order sigma-delta with an oversampling rate of 900 kHz. This analog input structure greatly simplifies transducer interfacing by providing a wide dynamic range for direct connection to the transducer and also simplifying the antialiasing filter design. A programmable gain stage in the current channel further facilitates easy transducer interfacing. A high pass filter in the current channel removes any dc component from the current signal. This eliminates any inaccuracies in the real power calculation due to offsets in the voltage or current signals--see HPF and Offset Effects section. The real power calculation is derived from the instantaneous power signal. The instantaneous power signal is generated by a direct multiplication of the current and voltage signals. In order to extract the real power component (i.e., the dc component), the instantaneous power signal is low-pass filtered. Figure 20 illustrates the instantaneous real power signal and shows how the real power information can be extracted by low-pass filtering the instantaneous power signal. This scheme correctly calculates real power for nonsinusoidal current and voltage waveforms at all power factors. All signal processing is carried out in the digital domain for superior stability over temperature and time. The low frequency output of the BL0955 is generated by accumulating this real power information. This low frequency inherently means a long accumulation time between output pulses. The output frequency is therefore proportional to the average real power. This average real power information can, in turn, be accumulated (e.g., by a counter) to generate real energy information. Because of its high output frequency and hence shorter integration time, the CF output is proportional to the instantaneous real power. This is
Address No.810, YiShan Road ShangHai China Tel 86-021-64850700 Fax 86-64852222 Zip.200233
BL0955 Single-Phase Energy MeteringIC (compatible with AD7755) useful for system calibration purposes that would take place under steady load conditions
Figure 20. Signal Processing Block Diagram . Power Factor Considerations
The method used to extract the real power information from the instantaneous power signal (i.e., by low-pass filtering) is still valid even when the voltage and current signals are not in phase. Figure 21 displays the unity
power factor condition and a DPF (Displacement Power Factor) = 0.5, i.e., current signal lagging the voltage by 60a . If we assume the voltage and current waveforms are sinusoidal, the real power component of the instantaneous power signal (i.e., the dc term) is given by
This is the correct real power calculation.
Address
No.810, YiShan Road ShangHai China Tel
86-021-64850700 Fax
86-64852222 Zip.200233
BL0955 Single-Phase Energy MeteringIC (compatible with AD7755)
Figure 21. DC Component of Instantaneous Power Signal Conveys Real Power Information PF<1
Nonsinusoidal Voltage and Current The real power calculation method also holds true for nonsinusoidal current and voltage waveforms. All voltage and current waveforms in practical applications will have some harmonic content. Using the Fourier Transform, instantaneous voltage and current waveforms can be expressed in terms of their harmonic content.
where:
v(t ) is the instantaneous voltage
V0 is the average value
Vh is the rms value of voltage harmonic h
and
h is the phase angle of the voltage harmonic.
where:
Address No.810, YiShan Road ShangHai China Tel 86-021-64850700 Fax 86-64852222 Zip.200233
BL0955 Single-Phase Energy MeteringIC (compatible with AD7755) i (t ) is the instantaneous current I 0 is the dc component
Ih is the rms value of current harmonic h
and
h is the phase angle of the current harmonic.
Using Equations 1 and 2, the real power P can be expressed in terms of its fundamental real power (P1) and harmonic real power (PH).
where
and
As can be seen from Equation 4 above, a harmonic real power component is generated for every harmonic, provided that harmonic is present in both the voltage and current waveforms. The power factor calculation has previously been shown to be accurate in the case of a pure sinusoid, therefore the harmonic real power must also correctly account for power factor since it is made up of a series of pure sinusoids. Note that the input bandwidth of the analog inputs is 14 kHz with a master clock frequency of 3.5795 MHz. ANALOG INPUTS Channel V1 (Current Channel ) The voltage output from the current transducer is connected to the BL0955 here. Channel V1 is a fully differential voltage input. V1P is the positive input with respect to V1N. The maximum peak differential signal on Channel 1 should be less than A 470 mV (330 mV rms for a pure sinusoidal signal) for specified operation. Note that Channel 1 has a programmable gain amplifier (PGA) with user selectable gain of 1, 2, 8 or 16 (see Table I). These gains facilitate easy transducer interfacing.
Address
No.810, YiShan Road ShangHai China Tel
86-021-64850700 Fax
86-64852222 Zip.200233
BL0955 Single-Phase Energy MeteringIC (compatible with AD7755)
Figure 22. Maximum Signal Levels, Channel 1, Gain=1 The diagram in Figure 22 illustrates the maximum signal levels on V1P and V1N. The maximum differential voltage is A 470 mV divided by the gain selection. The differential voltage signal on the inputs must be referenced to a common mode, e.g. AGND. The maximum common mode signal is A 100 mV as shown in Figure 22.
Channel V2 (Voltage Channel ) The output of the line voltage transducer is connected to the BL0955 at this analog input. Channel V2 is a fully differential voltage input. The maximum peak differential signal on Channel 2 is A 660 mV. Figure 23 illustrates the maximum signal levels that can be connected to the BL0955 Channel 2.
Figure 23. Maximum Signal Levels, Channel 2 Channel 2 must be driven from a common-mode voltage, i.e., the differential voltage signal on the input
Address No.810, YiShan Road ShangHai China Tel 86-021-64850700 Fax 86-64852222 Zip.200233
BL0955 Single-Phase Energy MeteringIC (compatible with AD7755) must be referenced to a common mode (usually AGND). The analog inputs of the BL0955 can be driven with common-mode voltages of up to 100 mV with respect to AGND. However best results are achieved using a common mode equal to AGND. Typical Connection Diagrams Figure 24 shows a typical connection diagram for Channel V1. ACT (current transformer) is the current transducer selected for this example. Notice the common-mode voltage for Channel 1 is AGND and is derived by center tapping the burden resistor to AGND. This provides the complementary analog input signals for V1P and V1N. The CT turns ratio and burden resistor Rb are selected to give a peak differential voltage of A 470 mV/ Gain at maximum load.
Figure 24. Typical Connection for Channel 1 Figure 25 shows two typical connections for Channel V2. The first option uses a PT (potential transformer) to provide complete isolation from the mains voltage. In the second option the BL0955 is biased around the neutral wire, and a resistor divider is used to provide a voltage signal that is proportional to the line voltage. Adjusting the ratio of Ra, Rb and VR is also a convenient way of carrying out a gain calibration on the meter.
Figure 25. Typical Connections for Channel 2 POWER SUPPLY MONITOR
Address
No.810, YiShan Road ShangHai China Tel
86-021-64850700 Fax
86-64852222 Zip.200233
BL0955 Single-Phase Energy MeteringIC (compatible with AD7755) The BL0955 contains an on-chip power supply monitor. The Analog Supply (AVDD) is continuously monitored by the BL0955. If the supply is less than 4 V A 5%, the BL0955 will be reset. This is useful to ensure correct device start-up at power-up and power-down. The power supply monitor has built in hysteresis and filtering. This gives a high degree of immunity to false triggering due to noisy supplies. As can be seen from Figure 26, the trigger level is nominally set at 4 V. The tolerance on this trigger level is about A 5%. The power supply and decoupling for the part should be such that the ripple at AVDD does not exceed 5 V A 5% as specified for normal operation.
_
Figure 26. On-Chip Power Supply Monitor HPF and Offset Effects Figure 27 shows the effect of offsets on the real power calculation. As can be seen, an offset on Channel 1 and Channel 2 will contribute a dc component after multiplication. Since this dc component is extracted by the LPF and used to generate the real power information, the offsets will have contributed a constant error to the real power calculation. This problem is easily avoided by enabling the HPF (i.e., pin AC/DC is set logic high) in Channel 1. By removing the offset from at least one channel, no error component can be generated at dc by the multiplication. Error terms at cos(wt ) are removed by the LPF and the digital-to-frequency conversion--see Digital-to-Frequency Conversion section.
{V cos(wt ) + Vos }x {I cos(wt ) + I os } = V x I x Vos x I os + Vos x I cos(wt ) + I os x V cos(wt ) + V x I x cos(2wt )
2 2
Address
No.810, YiShan Road ShangHai China Tel
86-021-64850700 Fax
86-64852222 Zip.200233
BL0955 Single-Phase Energy MeteringIC (compatible with AD7755)
Figure 27. Effect of Channel Offset on the Real Power Calculation The HPF in Channel 1 has an associated phase response that is compensated for on-chip. The phase compensation is activated when the HPF is enabled and is disabled when the HPF is not activated. Figures 28 and 29 show the phase error between channels with the compensation network activated. The BL0955 is phase compensated up to 1 kHz as shown. This will ensure correct active harmonic power calculation even at low power factors.
Figure 28. Phase Error Between Channels (0 Hz to 1 kHz)
Address
No.810, YiShan Road ShangHai China Tel
86-021-64850700 Fax
86-64852222 Zip.200233
BL0955 Single-Phase Energy MeteringIC (compatible with AD7755)
Figure 29. Phase Error Between Channels (40Hz to 70Hz) DIGITAL-TO-FREQUENCY CONVERSION As previously described, the digital output of the low-pass filter after multiplication contains the real power information. However since this LPF is not an ideal "brick wall" filter implementation, the output signal also contains attenuated components at the line frequency and its harmonics, i.e., cos(hwt ) where h = 1, 2, 3, . . . etc. The magnitude response of the filter is given by:
For a line frequency of 50Hz this would give an attenuation of the 2 w (100Hz) component of approximately -22dBs. The dominating harmonic will be at twice the line frequency, i.e., cos(2wt ) and this is due to the instantaneous power signal. Figure 30 shows the instantaneous real power signal at the output of the CPF which still contains a significant amount of instantaneous power information, i.e., cos(2wt ) . This signal is then passed to the digital-to-frequency converter where it is integrated (accumulated) over time in order to produce an output frequency. This accumulation of the signal will suppress or average out any non-dc components in the instantaneous real power signal. The average value of a sinusoidal signal is zero. Hence the frequency generated by the BL0955 is proportional to the average real power. Figure 30 shows the digital-to-frequency conversion for steady load conditions, i.e., constant voltage and current.
Address
No.810, YiShan Road ShangHai China Tel
86-021-64850700 Fax
86-64852222 Zip.200233
BL0955 Single-Phase Energy MeteringIC (compatible with AD7755)
Figure 30. Real Power-to-Frequency Conversion As can be seen in the diagram, the frequency output CF is seen to vary over time, even under steady load conditions. This frequency variation is primarily due to the cos(2wt ) component in the instantaneous real power signal. The output frequency on CF can be up to 2048 times higher than the frequency on F1 and F2. This higher output frequency is generated by accumulating the instantaneous real power signal over a much shorter time while converting it to a frequency. This shorter accumulation period means less averaging of the cos(2wt ) component. As a consequence, some of this instantaneous power signal passes through the digital-to-frequency conversion. This will not be a problem in the application. Where CF is used for calibration purposes, the frequency should be averaged by the frequency counter. This will remove any ripple. If CF is being used to measure energy, e.g., in a microprocessor-based application, the CF output should also be averaged to calculate power. Because the outputs F1 and F2 operate at a much lower frequency, a lot more averaging of the instantaneous real power signal is carried out. The result is a greatly attenuated sinusoidal content and a virtually ripple-free frequency output. Interfacing the BL0955 to a Microcontroller for Energy Measurement The easiest way to interface the BL0955 to a microcontroller is to use the CF high frequency output with the output frequency scaling set to 2048 A F1, F2. This is done by setting SCF = 0 and S0 = S1 = 1, see Table IV. With full-scale ac signals on the analog inputs, the output frequency on CF will be approximately 5.5 kHz. Figure 31 illustrates one scheme which could be used to digitize the output frequency and carry out the necessary averaging mentioned in the previous section.
Address
No.810, YiShan Road ShangHai China Tel
86-021-64850700 Fax
86-64852222 Zip.200233
BL0955 Single-Phase Energy MeteringIC (compatible with AD7755)
Figure 31. Interfacing the BL0955 to an MCU
As shown, the frequency output CF is connected to an MCU counter or port. This will count the number of pulses in a given integration time which is determined by an MCU internal timer. The average power is
proportional to the average frequency is given by:
The energy consumed during an integration period is given by:
For the purpose of calibration, this integration time could be 10 to 20 seconds in order to accumulate enough pulses to ensure correct averaging of the frequency. In normal operation the integration time could be reduced to one or two seconds depending, for example, on the required undate rate of a display. With shorter integration times on the MCU the amount of energy in each update may still have some small amount of ripple, even under steady load conditions. However, over a minute or more the measured energy will have no ripple. Power Measurement Considerations Calculating and displaying power information will always have some associated ripple that will depend on the integration period used in the MCU to determine average power and also the load. For example, at light loads the output frequency may be 10 Hz. With an integration period of two seconds, only about 20 pulses will be counted. The possibility of missing one pulse always exists as the BL0955 output frequency
Address No.810, YiShan Road ShangHai China Tel 86-021-64850700 Fax 86-64852222 Zip.200233
BL0955 Single-Phase Energy MeteringIC (compatible with AD7755) is running asynchronously to the MCU timer. This would result in a one-in-twenty or 5% error in the power measurement. TRANSFER FUNCTION Frequency Outputs F1 and F2 The BL0955 calculates the product of two voltage signals (on Channel 1 and Channel 2) and then low-pass filters this product to extract real power information. This real power information is then converted to a frequency. The frequency information is output on F1 and F2 in the form of active low pulses. The pulse rate at these outputs is relatively low, e.g., 0.34 Hz maximum for ac signals with S0 = S1 = 0--see Table III. This means that the frequency at these outputs is generated from real power information accumulated over a relatively long period of time.The result is an output frequency that is proportional to the average real power. The averaging of the real power signal is implicit to the digital-to-frequency conversion. The output frequency or pulse rate is related to the input voltage signals by the following equation.
where: Freq = Output frequency on F1 and F2 (Hz) V1 = Differential rms voltage signal on Channel 1 (volts) V2 = Differential rms voltage signal on Channel 2 (volts) Gain = 1, 2, 8 or 16, depending on the PGA gain selection made using logic inputs G0 and G1
V REF = The reference voltage (2.5 V A
8%) (volts)
F1- 4 = One of four possible frequencies selected by using the
logic inputs S0 and S1--see Table II.
NOTE * F1- 4 is a binary fraction of the master clock and therefore will vary if the specified CLKIN frequency is altered.
Example 1
Address
No.810, YiShan Road ShangHai China Tel
86-021-64850700 Fax
86-64852222 Zip.200233
BL0955 Single-Phase Energy MeteringIC (compatible with AD7755) Thus if full-scale differential dc voltages of +470 mV and -660 mV are applied to V1 and V2 respectively (470 mV is the maximum differential voltage that can be connected to Channel 1 and 660 mV is the maximum differential voltage that can be connected to Channel 2), the expected output frequency is calculated as follows:
NOTE: If the on-chip reference is used, actual output frequencies may vary from device to device due to reference tolerance of A 8%.
Example 2 In this example, with ac voltages of A 470 mV peak applied to V1 and A expected output frequency is calculated as follows: 660 mV peak applied to V2, the
NOTE: If the on-chip reference is used, actual output frequencies may vary from device to device due to reference tolerance of A 8%.
As can be seen from these two example calculations, the maximum output frequency for ac inputs is always half of that for dc input signals. Table III shows a complete listing of all maximum output frequencies.
Address
No.810, YiShan Road ShangHai China Tel
86-021-64850700 Fax
86-64852222 Zip.200233
BL0955 Single-Phase Energy MeteringIC (compatible with AD7755)
Frequency Output CF The pulse output CF (Calibration Frequency) is intended for use during calibration. The output pulse rate on CF can be up to 2048 times the pulse rate on F1 and F2. The lower the F1-4 frequency selected, the higher the CF scaling (except for the high frequency mode SCF = 0, S1 = S0 = 1). Table IV shows how the two frequencies are related, depending on the states of the logic inputs S0, S1 and SCF. Because of its relatively high pulse rate, the frequency at this logic output is proportional to the instantaneous real power. As is the case with F1 and F2, the frequency is derived from the output of the low-pass filter after multiplication. However, because the output frequency is high, this real power information is accumulated over a much shorter time. Hence less averaging is carried out in the digital-to-frequency conversion. With much less averaging of the real power signal, the CF output is much more responsive to power fluctuations--see Signal Processing Block in Figure 20.
SELECTING A FREQUENCY FOR AN ENERGY METER APPLICATION As shown in Table II, the user can select one of four frequencies. This frequency selection determines the maximum frequency on F1 and F2. These outputs are intended to be used to drive the energy register (electromechanical or other). Since only four different output frequencies can be selected, the available frequency selection has been optimized for a meter constant of 100 imp/kWhr with a maximum current of between 10 A and
Address No.810, YiShan Road ShangHai China Tel 86-021-64850700 Fax 86-64852222 Zip.200233
BL0955 Single-Phase Energy MeteringIC (compatible with AD7755) 120 A. Table V shows the output frequency for several maximum currents (IMAX) with a line voltage of 220 V. In all cases the meter constant is 100 imp/kWhr.
The F1-4 frequencies allow complete coverage of this range of output frequencies on F1 and F2. When designing an energy meter the nominal design voltage on Channel 2 (voltage) should be set to half-scale to allow for calibration of the meter constant. The current channel should also be no more than half-scale when the meter sees maximum load. This will allow over current signals and signals with high crest factors to be accommodated. Table VI shows the output frequency on F1 and F2 when both analog inputs are half-scale. The frequencies listed in Table VI align very well with those listed in Table V for maximum load.
When selecting a suitable F1-4 frequency for a meter design, the frequency output at IMAX (maximum load) with a meter constant of 100 imp/kWhr should be compared with Column 4 of Table VI. The frequency that is closest in Table VI will determine the best choice of frequency F1-4 . For example, if a meter with a maximum current of 25 A is being designed, the output frequency on F1 and F2 with a meter constant of 100 imp/ kWhr is 0.153 Hz at 25 A and 220 V (from Table V). Looking at Table VI, the closest frequency to 0.153 Hz in column four is 0.17 Hz. Therefore F2 (3.4 Hz--see Table II) is selected for this design. Frequency Outputs
Address
No.810, YiShan Road ShangHai China Tel
86-021-64850700 Fax
86-64852222 Zip.200233
BL0955 Single-Phase Energy MeteringIC (compatible with AD7755) Figure 1 shows a timing diagram for the various frequency outputs. The outputs F1 and F2 are the low frequency outputs that can be used to directly drive a stepper motor or electromechanical impulse counter. The F1 and F2 outputs provide two alternating low going pulses. The pulsewidth ( t1 ) is set at 275 ms and the time between the falling edges of F1 and F2 ( t 2 ) is approximately half the period of F1 ( t 2 ). If however the period of F1 and F2 falls below 550 ms (1.81 Hz) the pulsewidth of F1 and F2 is set to half of their period. The maximum output frequencies for F1 and F2 are shown in Table III. The high frequency CF output is intended to be used for communications and calibration purposes. CF produces a 90 ms wide active high pulse ( t 4 ) at a frequency proportional to active power. The CF output frequencies are given in Table IV. As in the case of F1 and F2, if the period of CF ( t 5 ) falls below 180 ms, the CF pulsewidth is set to half the period. For example, if the CF frequency is 20 Hz, the CF pulsewidth is 25 ms. NOTE: When the high frequency mode is selected, (i.e., SCF = 0, S1 = S0 = 1) the CF pulsewidth is fixed at 18 us . Therefore t 4 will always be 18 us , regardless of output frequency on CF. NO LOAD THRESHOLD The BL0955 also includes a "no load threshold" and "start-up current" feature that will eliminate any creep effects in the meter. The BL0955 is designed to issue a minimum output frequency on all modes except when SCF = 0 and S1 = S0 = 1. The no-load detection threshold is disabled on this output mode to accommodate specialized application of the BL0955. Any load generating a frequency lower than this minimum frequency will not cause a pulse to be issued on F1, F2 or CF. The minimum output frequency is given as 0.0014% of the full-scale output frequency for each of the F1-4 frequency selections--see Table II. For example, an energy meter with a meter constant of 100 imp/kWhr on F1, F2 using F2 (3.4 Hz), the maximum output frequency at F1 or F2 would be 0.0014% of 3.4 Hz or 4.76A 10-5 Hz. This would be 3.05 A 10-3 Hz at CF (64 A F1 Hz). In this example the no-load threshold would be equivalent to 1.7 W of load or a start-up current of 8 mA at 220 V. Comparing this value to the IEC1036 specification which states that the meter must start up with a load equal to or less than 0.4% Ib. For a 5A (Ib) meter 0.4% of Ib is equivalent to 20 mA.
Address
No.810, YiShan Road ShangHai China Tel
86-021-64850700 Fax
86-64852222 Zip.200233
BL0955 Single-Phase Energy MeteringIC (compatible with AD7755)
OUTLINE DIMENSIONS Dimensions shown in inches and (mm).
Address
No.810, YiShan Road ShangHai China Tel
86-021-64850700 Fax
86-64852222 Zip.200233


▲Up To Search▲   

 
Price & Availability of BL0955

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X